11 Nooc oo ah Cudurka Neefsashada

Sharaxaad Gaaban:

Qalabkan waxa loo isticmaalaa ogaanshaha tayada in vitro ee cudurada caadiga ah ee neef-mareenka ee ku jira xaakada bini'aadamka, oo ay ku jiraan Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumonialtno Bortephia (Khomonade) pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Lug). Natiijooyinka waxaa loo isticmaali karaa gargaar ahaan ogaanshaha bukaannada isbitaallada la dhigay ama aadka u xanuunsan ee looga shakisan yahay infekshannada bakteeriyada ee habka neefsashada.Qalabkan waxa loo isticmaalaa ogaanshaha tayada in vitro ee cudurada caadiga ah ee neef-mareenka ee ku jira xaakada bini'aadamka, oo ay ku jiraan Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumonialtno Bortephia (Khomonade) pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Lug). Natiijooyinka waxaa loo isticmaali karaa gargaar ahaan ogaanshaha bukaannada isbitaallada la dhigay ama aadka u xanuunsan ee looga shakisan yahay infekshannada bakteeriyada ee habka neefsashada.


Faahfaahinta Alaabta

Tags Product

Magaca alaabta

HWTS-RT162A 11 Noocyada Qalabka Lagu Ogaado Ashitada Nukliyeerka ee Neefsashada(Fluorescence PCR)

Kanaalka

靶标 Kanaalka
核酸反应液A 核酸反应液B 核酸反应液C 核酸反应液D
HI Smet MP Lugta FAM
SP PA Bp / CY5
KPN ABA Bpp Cpn ROX
内参 内参 内参 内参 VIC/HEX

Epidemiology

Xanuunada ku dhaca hab-mareenka neef-mareenku waa qayb muhiim ah oo ka mid ah cudurrada khatarta weyn ku ah caafimaadka bini’aadamka, waxaanay cilmi-baadhisyadu caddeeyeen in inta badan caabuqa hab-mareenka-mareenka ay sababaan cudurrada bakteeriyada iyo fayras-ku-wadayaasha ah oo wada-qaada qofka martida ah, taasina ay keento darnaanta cudurka iyo xitaa dhimasho, sidaas awgeed caddaynta cudur-sidaha cudur-sidaha waxay u oggolaanaysaa in si gaar ah loo daweeyo, waxaanay hagaajinaysaa heerka badbaadada bukaanka.[1,2].

Qiyaasta Farsamada

Kaydinta

≤-18℃

Nolosha shelf 12 bilood
Nooca Tuunada xaako
Ct HI,SP,KPN,PA,ABA,Smet:Ct≤33BP, Bpp, MP, Cpn, Lugta: Ct≤38
CV <5.0%
LoD Klebsiella oof wareenka, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia iyo Legionellapneumophila: 1000 CFU/ml;

xiiq-dheerta Bordetella iyo Bacillus parapertussis: 500 CFU/mL;

Mycoplasma pneumoniae iyo Chlamydia pneumoniae: 200 koobi/mL.

Gaar ahaan Natiijooyinka tijaabada falcelinta iskutallaabtu waxay muujisay in aysan jirin falcelin iskutallaab ah oo udhaxeysa xirmadan iyo Cytomegalovirus, fayraska Herpes simplex nooca 1, fayraska Varicella-zoster, fayraska Epstein-Barr, xiiq-dheerta Bordetella, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella, Molisinshala straxella, Molisophila straxella, Molisella, Molisinshala, Molisella straxella, Molisella straxella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, Molisella, iyo Molisella straxella. Qaaxada mycobacterium, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas Burholder Burktumbacteria, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiruveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Klebsiella pneumoniae, Klebsiella pneumoniae, Chlamydia.
Qalabka lagu dabaqi karo Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah

Hababka noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah ee degdega ah

QuantStudio®5 Nidaamyada PCR-waqtiga-dhabta ah

SLAN-96P Nidaamyada PCR-Waqtiga-dhabta ah

LightCycler®480 Nidaamka PCR-waqtiga dhabta ah

LineGene 9600 Plus-Waqtiga dhabta ah ee PCR Nidaamyada ogaanshaha

MA-6000-waqtiga-dhabta ah ee cabbirka kulaylka wareegga

BioRad CFX96 Nidaamka PCR-waqtiga-dhabta ah

BioRad CFX Opus 96 Nidaamka PCR-waqtiga-dhabta ah

Socodka Shaqada

Makro & Micro-Test DNA / RNA Kit (HWTS-3019) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ku dar 200µL eenafsiyeedmilix ilaa da'da la warshadeeyay, iyo talaabooyinka xiga waa in lagu fuliyaa si waafaqsan tilmaamaha. Mugga caddaynta lagu taliyey waa 100 µL.


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir