17 Noocyada HPV (16/18/6/11/44 Qorista)

Sharaxaad Gaaban:

Qalabkani wuxuu ku haboon yahay in lagu ogaado tayada 17 nooc ee papillomavirus aadanaha (HPV) noocyada (HPV 6, 11, 16,18,31, 33,35, 39, 44,45, 51, 52.56,58, 59,66). 68) qaybo gaar ah oo nucleic acid ah oo ku jira muunada kaadida, muunada suufka ilmo-galeenka ee dheddigga iyo muunada suufka dheddigga, iyo HPV 16/18/6/11/44 oo wax ku qora si ay uga caawiso ogaanshaha iyo daawaynta caabuqa HPV.


Faahfaahinta Alaabta

Tags Product

Magaca alaabta

HWTS-CC015 17 Noocyada Fayraska Papillomavirus (16/18/6/11/44 Qorista) Qalabka lagu ogaado Acid Nukliyeer ah (Fluorescence PCR)

Epidemiology

Kansarka ilmo-galeenka waa mid ka mid ah burooyinka halista ah ee ugu badan ee ku dhaca habka taranka haweenka.Waxaa la muujiyay in caabuqa HPV ee joogtada ah iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo galeenka.Waqtigan xaadirka ah waxaa jira la'aanta daaweyn wax ku ool ah oo guud ahaan la aqbalay oo loogu talagalay kansarka ilmo-galeenka ee uu keeno HPV.Sidaa darteed, ogaanshaha hore iyo ka hortagga caabuqa afka ilmo-galeenka ee uu keeno HPV waa furayaasha ka hortagga kansarka ilmo-galeenka.Sameynta baaritaanno fudud, gaar ah oo degdeg ah oo lagu ogaanayo cudur-sidaha ayaa muhiimad weyn u leh ogaanshaha bukaan-socodka ee kansarka ilmo-galeenka.

Kanaalka

PCR-Mix1 FAM 18
VIC/HEX

16

ROX

31,33,35,39,45,51,52,56,58,59,66,68

CY5 Xakamaynta gudaha
PCR-Mix2 FAM 6
VIC/HEX

11

ROX

44

CY5 Xakamaynta gudaha

Qiyaasaha Farsamada

Kaydinta

-18℃

Nolosha shelf 12 bilood
Nooca Tuunada Muunadda kaadida, muunadda suufka ilmo-galeenka ee dheddigga, muunadda suufka dheddigga
Ct ≤28
LoD 300 koobi/ml
Gaar ahaan Ma jiro falcelin iskutallaab ah oo leh Ureaplasma urealyticum, Chlamydia trachomatis ee mareenka taranka, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Caar, Gardnerella iyo noocyada kale ee HPV ee aan daboolin xirmada.
Qalabka lagu dabaqi karo Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah
Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah ee degdegga ah
QuantStudio®5 Nidaamyada PCR-waqtiga-dhabta ah
SLAN-96P Nidaamyada PCR-waqtiga-dhabta ah
LightCycler®480 Nidaamyada PCR-waqtiga-dhabta ah
LineGene 9600 Plus-Waqtiga dhabta ah ee PCR Nidaamyada ogaanshaha
MA-6000-waqtiga-dhabta ah ee cabbirka kulaylka wareegga
BioRad CFX96 Nidaamka PCR-waqtiga-dhabta ah
BioRad CFX Opus 96 Nidaamka PCR-waqtiga-dhabta ah

Socodka Shaqada

Soo saarista lagu taliyay: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaaso loo isticmaali karo Macro & Micro-Test Soo saarista Ashitada Nucleic Acid (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ku dar 200μL ee cusbada caadiga ah si aad dib ugu soo celiso pellet ee tallaabada 2.1, ka dibna soo saarista waa in lagu sameeyaa si waafaqsan Tilmaamaha isticmaalka reagent soo saarida.Mugga sare ee lagu taliyey waa 80μL.

Soo saarista lagu taliyay: QIAamp DNA Mini Kit (51304) ama Makro & Micro-Tijaabo Viral DNA/RNA Column (HWTS-3020-50).Ku dar 200μL oo cusbo ah oo caadi ah si aad dib ugu celiso pellet-ka tallaabada 2.1, ka dibna soo saarista waa in loo fuliyaa si waafaqsan tilmaamaha isticmaalka reagent soo saarista.Mugga muunada la soo saaray ee shaybaarada ayaa dhamaantood ah 200μL, mugga sare ee lagu taliyeyna waa 100μL.

Soo saarista lagu taliyay: Macro & Micro-Tijaabada Tusaalaha Siidaynta Reagent (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L).Ku dar 200μL oo muunad reageent ah si aad dib ugu celiso pellet-ka tallaabada 2.1, ka dibna soo saarista waa in loo fuliyaa si waafaqsan tilmaamaha isticmaalka reagent soo saarida.


  • Hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir