Nooca Asiidhka Nukliyeerka Nooca 41 ee Adenovirus
Magaca alaabta
Qalabka Baadhista Aashitada Nukliyeerka ee HWTS-RT113-Adenovirus Nooca 41 (Fluorescence PCR)
Cudurrada Faafa
Fayraska Adenovirus (Adv) wuxuu ka tirsan yahay qoyska Adenovirus. Adv wuxuu ku faafi karaa oo uu ku keeni karaa cudur unugyada marinnada neefsashada, marinnada caloosha iyo mindhicirka, kaadi mareenka, iyo conjunctiva. Inta badan waxaa lagu qaadaa marinnada caloosha iyo mindhicirka, marinnada neefsashada ama xiriirka dhow, gaar ahaan barkadaha dabaasha oo aan lahayn jeermis dile ku filan, taas oo kordhin karta fursadda gudbinta oo sababi karta faafitaan [1-2]. Adv wuxuu inta badan ku dhacaa carruurta. Caabuqyada marinnada caloosha iyo mindhicirka ee carruurta badanaa waa nooca 40 iyo 41 ee kooxda F. Inta badan ma laha calaamado caafimaad, qaarkoodna waxay keenaan shuban carruurta. Habka ficilkiisu waa inuu duulo xuubka yar ee xiidmaha carruurta, taasoo ka dhigaysa unugyada epithelial ee xuubka xiidmaha inay yaraadaan oo ay gaaban yihiin, unugyaduna way burburaan oo milmaan, taasoo keenta cillad nuugista xiidmaha iyo shuban. Xanuunka caloosha iyo bararka ayaa sidoo kale dhici kara, xaaladaha daranna, habdhiska neefsashada, habdhiska dhexe ee neerfaha, iyo xubnaha ka baxsan xiidmaha sida beerka, kelyaha, iyo ganaca ayaa laga yaabaa inay ku lug yeeshaan cudurkuna wuu sii xumaan karaa.
Halbeegyada Farsamada
| Kaydinta | ≤-18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | saxaro |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 300Nuqullo/mL |
| Gaar ahaanshaha | Ku celcelinta: Isticmaal qalabka si aad u ogaato tixraaca ku celcelinta shirkadda. Ku celi tijaabada 10 jeer iyo CV≤5.0%. Gaar ah: Isticmaal qalabka si aad u tijaabiso tixraaca taban ee shirkadda caadiga ah, natiijooyinku waa inay buuxiyaan shuruudaha u dhigma |
| Qalabka Khuseeya | Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah, Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah, QuantStudio®5 Nidaamyada PCR-ga Waqtiga-dhabta ah, Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.), LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480, Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer), Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.) |
Socodka Shaqada
Qalabka DNA/RNA ee Macro & Micro-Test Viral (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. ayaa lagu talinayaa in la soo saaro muunadda, tallaabooyinka xigana waa in si adag loo sameeyaa iyadoo la raacayo IFU-ga Qalabka.