Chlamydia Trachomatis, Neisseria GONORORHOEAE iyo Trichomonas Siilka

Sharraxaadda Gaaban:

Qalabka waxaa loogu talagalay ogaanshaha tayada tareenka ee cudurka Chlamydia Traclamatomas (CT), Neisseria Gonrorrhoeae (NG)iyoTrichomonal Vacaritis (TV) oo ku jira suufka lab ee lab, dheddigga ilmo galeenka afka ilmo-galeenka, iyo saadaasha siilka xubinta taranka ee siilka, oo ay gargaar siiso baaritaanka iyo daaweynta bukaannada qaba infekshannada dhabta ah.


Si faahfaafo

Calaamadaha wax soo saarka

Magaca wax soo saarka

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonrrorhoeae iyo Trichomonas Siiad acid Nucleic acid Hutc (PCR)

Nadiifin

Chlamydia trachomatis (CT) waa nooc ka mid ah microorganity prokaryartic-ka oo si adag ugu salatahay unugyada Eukaryotic. Chlamydia trachomatia-ka waxaa loo qaybiyaa ak motioties iyadoo la raacayo habka 'serotypeypeypeypeypeype'. Infekshinka kaadi-mareenka waxaa badanaa keena cudurka bayooloji ee trakomoma byroma pottomas-ka ah.

Kanaal

Fa farqad Chlamydia trachomatis
Rox Neisseria gonrrorhoheae
Cy5 Trichomonal Vacaritis
Vic / hex Kontoroolka gudaha

Cayayaanka farsamada

Bakhaar

-18 ℃

Shelf-Life 12 bilood
Nooca muunadda Dheddig ilmo-galeenka ilmo galeenka,Hadiyadda siilka ee siilka ah,Maraakiibta u kaadinaya
Ct ≤38
CV <5%
Dhigid 400Nuqulo / ml
Si gaar ah Ma jiro wax-dhaaf ah iskutallaab-celin ah oo lagula jiro cudurrada kale ee cudurka STD ee ka baxsan meesha loo kala baxo ee xirmada tijaabada, sida treponema palligal, mycoplasma semetionium Nooca 1, Candida Albicans, iwm.
Aaladaha lagu dabaqi karo Dosystems-ka lagu dabaqay 7500 Nidaamka PCR-ka dhabta ah

Waxaa lagu dabaqay bio-yariyada bio-yada lagu dabaqay 7500 oo si dhakhso leh u ah nidaamyada PCR-ga

TiarStudio®5 Nidaamyada PCR-ka waqtiga-dhabta ah

Nidaamyada 'Slacan-96p' ee waqtiga dhabta ah ee PCR

Nalalka®480 Nidaamka PCR-ka dhabta ah

Sadarka 9600 oo lagu daray nidaamka ogaanshaha PCR-ka waqtiga-dhabta ah

MA-6000 baaskiil-ku-meel-gaadhka waqtiga-ku-meel-gaarka ah

Biorad Cfx96 Nidaamka waqtiga-dhabta ah ee PCR

Biorad Cfx Opus 96 Nidaamka PCR-ka waqtiga-dhabta ah

Socodka shaqada

Xulashada 1.

Soosaarka lagu taliyay ee Reaggent: Pipette 1Ml ee muunadda in lagu tijaabiyo tubbada 1.5ml ee 'DNASE / RNASE-Centrifuge', Centrifm muddo 12 daqiiqo ah, iska tuur supernit-ka oo xaji miiska. Ku dar 200μl oo cusbo caadi ah oo cusbada caadiga ah si aad u soo celiso. Macro-peral Guud guud (Hwts-3006c, hwts-3006b)) oo ay ku qoran tahay Jiangsu Macro & Micro-Tijaabada Med-Tech Conact Co., Ltd. Soosaarka waa in loo sameeyaa iyadoo loo eegayo tilmaamaha isticmaalka. Mugga muunad ee muunad la soo saaray waa 200μl, oo mugga oraahda lagu talinayo waa 80μl.

Xulashada 2.

Soosaarista lagu taliyay Reagent: Soo-saarista aashitada nucleic acid ama xirmada nadiifinta (YDP302). Soosaarista waa in loo sameeyaa si adag iyadoo loo eegayo tilmaamaha loo adeegsado. Mugga oraahda lagu taliyey waa 80μl.


  • Hore:
  • Xiga:

  • Halkan ku qor farriintaada oo noo soo dir