Chlamydia Trachomatis, Neisseria Gonorrhoeae iyo Trichomonas vaginalis

Sharaxaad Gaaban:

Qalabka waxaa loogu talagalay in lagu ogaado tayada Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) in vitro.iyoTrichomonal vaginitis (TV) oo ku jirta suufka kaadi mareenka ragga, suufka afka ilmo-galeenka dumarka, iyo muunadaha suufka siilka dumarka, waxayna gacan ka geystaan ​​​​baaritaanka iyo daaweynta bukaanada qaba caabuqyada marinnada kaadi mareenka.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca alaabta

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae iyo Trichomonas vaginalis Qalabka Ogaanshaha Aashitada Nucleic (Fluorescence PCR)

Cudurrada Faafa

Chlamydia trachomatis (CT) waa nooc ka mid ah noolaha prokaryotic-ga ah oo si adag ugu dulinsan unugyada eukaryotic-ga. Chlamydia trachomatis waxa loo qaybiyaa noocyada AK iyadoo loo eegayo habka serotype-ka. Caabuqyada marinnada kaadi mareenka waxaa inta badan sababa noocyada kala duwan ee trachoma ee bayoolojiga DK, raggana waxaa badanaa loo muujiyaa inay yihiin urethritis, kaas oo la daweyn karo iyada oo aan la daaweyn, laakiin intooda badan waxay noqdaan kuwo daba-dheeraada, marmarna ka sii dara, waxaana lagu dari karaa epididymitis, proctitis, iwm.

Kanaal

FAM Chlamydia trachomatis
ROX Neisseria gonorrhoeae
CY5 Cudurka xubinta taranka ee Trichomonal
VIC/HEX Xakamaynta Gudaha

Halbeegyada Farsamada

Kaydinta

-18℃

Muddada khaanadaha 12 bilood
Nooca Muunada Suufka ilmo-galeenka dumarka,Suufka siilka ee dumarka,Suufka kaadi mareenka ee ragga
Ct ≤38
CV <5%
LoD 400Nuqullo/mL
Gaar ahaanshaha Ma jiro wax falcelin isdhaafsi ah oo lala sameeyo jeermisyada kale ee caabuqa STD-ga ee ka baxsan heerka ogaanshaha ee qalabka baaritaanka, sida Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus nooca 1, Herpes simplex virus nooca 2, Candida albicans, iwm.
Qalabka Khuseeya Nidaamka PCR-ga ee Waqtiga-dhabta ah ee La Adeegsaday ee Biosystems 7500

Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah

QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah

Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P

LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480

Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah

Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96

Socodka Shaqada

Ikhtiyaarka 1aad.

Waxyaabaha lagu taliyay ee soo saarista: Pipette 1mL oo muunadda ah oo lagu tijaabinayo 1.5mL oo ah tuubo centrifuge ah oo aan lahayn DNase/RNase, centrifuge-ka 12000rpm muddo 3 daqiiqo ah, iska tuur dareeraha oo hay qulqulka. Ku dar 200µL oo cusbo caadi ah qulqulka si aad dib ugu soo celiso. Qalabka Guud ee DNA/RNA ee Macro & Micro-Test (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Soo saarista waa in la sameeyaa iyadoo la raacayo tilmaamaha isticmaalka. Mugga muunadda la soo saaray waa 200µL, mugga soo saarista ee lagu taliyayna waa 80µL.

Ikhtiyaarka 2aad.

Waxyaabaha lagu taliyay ee soo saarista: Qalabka Soo saarista Aashitada Nukliyeerka ama Nadiifinta (YDP302). Soo saarista waa in si adag loo sameeyaa iyadoo la raacayo tilmaamaha loo isticmaalo. Mugga soo saarista ee lagu taliyay waa 80µL.


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir