Fayraska Encephalitis B ee Nucleic Acid

Sharaxaad Gaaban:

Qalabkan waxaa loo isticmaalaa in lagu ogaado tayada fayraska encephalitis B ee ku jira seeramka iyo balaasmaha bukaanada in vitro.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca alaabta

Qalabka Baadhista Aashitada Nucleic ee Fayraska B ee HWTS-FE003 (Fluorescence PCR)

Cudurrada Faafa

Cudurka encephalitis-ka ee Japan waa cudur faafa oo dhiigga ku faafa, kaasoo aad u waxyeello u leh caafimaadka iyo nolosha bukaanada. Ka dib marka qofku uu ku dhaco fayraska encephalitis-ka ee B, ka dib qiyaastii 4 ilaa 7 maalmood oo uu ku jiro, tiro badan oo fayras ah ayaa ku faafa jirka, fayraskuna wuxuu ku faafaa unugyada beerka, beeryarada, iwm. Tiro yar oo bukaanno ah (0.1%), fayraska ku jira jirka wuxuu sababi karaa barar ku dhaca xuubka maskaxda iyo unugyada maskaxda. Sidaa darteed, ogaanshaha degdegga ah ee fayraska encephalitis-ka ee B waa furaha daaweynta encephalitis-ka ee Japan, iyo sameynta hab fudud oo gaar ah oo degdeg ah oo lagu ogaanayo cudurka etiological-ka ayaa muhiimad weyn u leh ogaanshaha kiliinikada ee encephalitis-ka Japan.

Halbeegyada Farsamada

Kaydinta

-18℃

Muddada khaanadaha 9 bilood
Nooca Muunada muunadaha seeramka, balaasmaha
CV ≤5.0%
LoD 2000 Nuqul/mL
Qalabka Khuseeya Waxaa lagu dabaqi karaa nooca I ee wax soo saarka ogaanshaha:Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah,QuantStudio®5 Nidaamyada PCR-ga Waqtiga-dhabta ah,

Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.),

Nidaamyada Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A,Tiknoolajiyadda Hangzhou Bioer),

Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.),

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX96,

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96.

Waxaa lagu dabaqi karaa nooca II ee wax soo saarka ogaanshaha:

EudemonTMAIO800 (HWTS-EQ007) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Socodka Shaqada

Qalabka Guud ee Baaritaanka Macro & Micro-Test DNA/RNA (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extracter Lambarka Dukumentiga: HWTS-STP-IFU-JEV Lambarka Buugga: HWTS-FE003A (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Soo saarista waa in lagu bilaabaa iyadoo loo eegayo IFU-ga falgalka soo saarista. Mugga muunadda la soo saaray waa 200μL mugga soo saarista lagu taliyayna waa 80 μL.


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir