Fayraska Hargabka A/ Fayraska Hargabka B

Sharaxaad Gaaban:

Qalabkan waxaa loo isticmaalaa in lagu ogaado tayada fayraska hargabka A iyo fayraska hargabka B ee RNA ee muunadaha suufka afka ee aadanaha.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca alaabta

Qalabka Baadhista A ee Fayraska/ Fayraska Influenza B ee HWTS-RT174 (Fluorescence PCR)

Cudurrada Faafa

Iyada oo lagu saleynayo farqiga antigenic ee u dhexeeya hidda-wadaha NP iyo hidda-wadaha M, fayrasyada hargabka waxaa loo qaybin karaa afar nooc: fayraska hargabka A (IFV A), fayraska hargabka B (IFV B), fayraska hargabka C (IFV C) iyo fayraska hargabka D (IFV D)[1]Fayraska Hargabka A wuxuu leeyahay noocyo badan oo martigeliyayaal ah iyo noocyo isku dhafan, wuxuuna heli karaa awoodda uu ugu faafo martida iyada oo loo marayo isku-darka hidde-sidaha iyo isbeddellada la-qabsiga. Aadanuhu ma laha difaac waara oo ka dhan ah fayraska hargabka A, sidaa darteed dadka da' kasta leh guud ahaan waa u nugul yihiin. Fayraska Hargabka A waa cudur-sidaha ugu weyn ee sababa masiibooyinka hargabka.[2]Fayraska hargabka B wuxuu inta badan ku badan yahay meel yar mana laha noocyo hoosaadyo ah. Kuwa ugu waaweyn ee sababa caabuqa aadanaha waa nooca B/Yamagata ama nooca B/Victoria. Kiisaska la xaqiijiyay ee hargabka ee ka dhaca 15 waddan oo ku yaal gobolka Aasiya-Baasifigga bil kasta, heerka la xaqiijiyay ee fayraska hargabka B waa 0-92%[3]Si ka duwan fayraska hargabka A, kooxo gaar ah sida carruurta iyo waayeelka ayaa u nugul fayraska hargabka B waxayna u nugul yihiin dhibaatooyin, taas oo culays ka weyn ku haysa bulshada marka loo eego fayraska hargabka A.[4].

Kanaal

FAM Aashitada nukliyeerka MP
ROX

Xakamaynta Gudaha

Halbeegyada Farsamada

Kaydinta

≤-18℃

Muddada khaanadaha 12 bilood
Nooca Muunada Muunad suuf ah oo afka laga qaato
Ct Hargabka A, Hargabka BCt≤35
CV <5.0%
LoD Hargabka A iyo Hargabka Bdhammaantood waa 200 Nuqul/mL
Gaar ahaanshaha

Falcelinta Isdhaafsiga: Ma jiro falgal isdhaafsi ah oo u dhexeeya qalabka iyo Bocavirus, rhinovirus, cytomegalovirus, fayraska isku-dhafka neefsashada, fayraska parainfluenza, fayraska Epstein-Barr, fayraska herpes simplex, fayraska Varicella-zoster, fayraska mumps, enterovirus, fayraska jadeecada, fayraska metapneumovirus ee aadanaha, adenovirus, fayraska coronavirus ee aadanaha, coronavirus-ka cusub, fayraska SARS, fayraska MERS, rotavirus, norovirus, Chlamydia pneumoniae, Mycoplasma pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumocystis carinii, Haemophilus influenzae, Bordetella pertussis, Staphylococcus aureus, Mycobacterium TB, Neisseria gonorrhoeae, Candida albicans, Candida glabrata, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivary, Moraxella catarrhalis, Lactobacillus, Bakteeriyada Corynebacterium, iyo DNA-da hidde-sideyaasha aadanaha.

Baaritaanka faragelinta: Xullo mucin (60 mg/mL), dhiigga aadanaha (50%), phenylephrine (2 mg/mL), oxymetazoline (2 mg/mL), sodium chloride (20 mg/mL) oo leh 5% ilaaliye, beclomethasone (20 mg/mL), dexamethasone (20 mg/mL), flunisolide (20 μg/mL), triamcinolone acetonide (2 mg/mL), budesonide (1 mg/mL), mometasone (2 mg/mL), fluticasone (2 mg/mL), histamine hydrochloride (5 mg/mL), benzocaine (10%), menthol (10%), zanamivir (20 mg/mL), peramivir (1 mg/mL), mupirocin (20 mg/mL), tobramycin (0.6 mg/mL), oseltamivir (60ng/mL), ribavirin (10 mg/L) baaritaannada faragelinta, natiijooyinkuna waxay muujinayaan in walxaha faragelinta leh ee ku jira xaddiga kor ku xusan aysan faragelin ogaanshaha qalabka.

Qalabka Khuseeya Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee La Adeegsaday ee Biosystems 7500

QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah

Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah

Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96

Socodka Shaqada

Qalabka DNA/RNA ee Viral-ka ee Macro & Micro-Test (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.waxaa lagula talinayaa soo saarista muunadda iyotallaabooyinka xiga waa inay ahaadaansameesi adag oo waafaqsan IFUQalabka.