Cudurka Oof-wareenka Mycoplasma (MP)

Sharaxaad Gaaban:

Badeecadan waxaa loo isticmaalaa in lagu ogaado tayada in vitro ee aashitada nucleic-ga Mycoplasma pneumoniae (MP) ee muunadaha xaakada aadanaha iyo suufka afka.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca alaabta

Qalabka Baadhista Aashitada Nukliyeerka ee HWTS-RT024 (MP)

Cudurrada Faafa

Mycoplasma pneumoniae (MP) waa nooc ka mid ah noolaha ugu yar ee prokaryotic, kaas oo u dhexeeya bakteeriyada iyo fayraska, oo leh qaab-dhismeedka unugyada laakiin aan lahayn derbi unug. MP waxay inta badan keentaa caabuq ku dhaca marinnada neefsashada ee aadanaha, gaar ahaan carruurta iyo dhallinyarada. Waxay sababi kartaa oof-wareenka mycoplasma ee aadanaha, caabuqa marinnada neefsashada ee carruurta iyo oof-wareen aan caadi ahayn. Calaamadaha caafimaadku way kala duwan yihiin, kuwaas oo intooda badan yihiin qufac daran, qandho, qarqaryo, madax-xanuun, cuna xanuun. Caabuqa marinnada neefsashada sare iyo oof-wareenka bronki ayaa ah kuwa ugu badan. Bukaannada qaar waxay ku dhici karaan caabuqa marinnada neefsashada sare ilaa oof-wareen daran, dhibaato neefsasho oo daran iyo dhimasho ayaa dhici karta.

Kanaal

FAM Mycoplasma pneumoniae
VIC/HEX

Xakamaynta Gudaha

Halbeegyada Farsamada

Kaydinta

≤-18℃

Muddada khaanadaha 12 bilood
Nooca Muunada Xaako, suufka afka
Ct ≤38
CV ≤5.0%
LoD 200 Nuqul/mL
Gaar ahaanshaha a) Falcelinta Isdhaafka ah: ma jiro falgal isdhaafsi ah oo lala sameeyo Ureaplasma urealyticum, Mycoplasma genitalium, Mycoplasma hominis, Streptococcus pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, Klebsiella pneumoniae, Staphylococcus aureus, Mycobacterium tuberculosis, Legionella pneumophila, Pseudomonas aeruginosa, Acinetobacter baumannii, Influenza A virus, Influenza B virus, Parainfluenza virus nooca I/II/III/IV, Rhinovirus, Adenovirus, Human metapneumovirus, Respiratory syncytial virus iyo human genomic nucleic acid.

b) Awoodda ka hortagga faragelinta: ma jirto faragelin marka walxaha faragelinta leh lagu tijaabiyay heerarka soo socda: hemoglobin (50mg/L), bilirubin (20mg/dL), mucin (60mg/mL), 10% (v/v) dhiigga aadanaha, levofloxacin (10μg/mL), moxifloxacin (0.1g/L), gemifloxacin (80μg/mL), azithromycin (1mg/mL), clarithromycin (125μg/mL), erythromycin (0.5g/L), doxycycline (50mg/L), minocycline (0.1g/L).

Qalabka Khuseeya Nidaamka PCR-ga ee Waqtiga-dhabta ah ee La Adeegsaday ee Biosystems 7500

Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah

QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah

Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.)

LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480

Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer)

Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.)

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96

Socodka Shaqada

(1) Muunad Xaako

Waxyaabaha lagu taliyay ee soo saarista: Qalabka DNA/RNA ee Macro & Micro-Test Viral (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ku dar 200µL oo cusbo caadi ah qulqulka la farsameeyay. Soo saarista xigta waa in la sameeyaa iyadoo loo eegayo tilmaamaha loo isticmaalo. Mugga soo saarista ee lagu taliyay waa 80µL. Waxyaabaha lagu taliyay ee soo saarista: Soo saarista Aashitada Nucleic ama Reagent Purification (YDP315-R). Soo saarista waa in si adag loo sameeyaa iyadoo loo eegayo tilmaamaha loo isticmaalo. Mugga soo saarista ee lagu taliyay waa 60µL.

(2) Suufka afka laga qaato

Qalabka soo saarista ee lagu taliyay: Qalabka Macro & Micro-Test Viral DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Soo saarista waa in la sameeyaa iyadoo la raacayo tilmaamaha loo isticmaalo. Mugga soo saarista ee lagu taliyay ee muunadda waa 200µL, mugga soo saarista ee lagu taliyayna waa 80µL. Qalabka soo saarista ee lagu taliyay: QIAamp Viral RNA Mini Kit (52904) ama Nucleic Acid Extract or Purification Reagent (YDP315-R). Soo saarista waa in si adag loo sameeyaa iyadoo la raacayo tilmaamaha loo isticmaalo. Mugga soo saarista muunadda lagu taliyay waa 140µL, mugga soo saarista lagu taliyayna waa 60µL.