SARS-CoV-2/hargabka A/hargabka B

Sharaxaad Gaaban:

Qalabkani wuxuu ku habboon yahay in vitro lagu ogaado tayada SARS-CoV-2, hargabka A iyo hargabka B nucleic acid ee sanbabada sanbabada iyo sanbabada suufka oropharyngeal taas oo ka mid ah dadka looga shakisan yahay infekshinka SARS-CoV-2, hargabka A iyo hargabka B. Waxa kale oo loo isticmaali karaa kiisaska looga shakisan yahay iyo pf. aqoonsiga SARS-CoV-2, hargabka A iyo hargabka B nucleic acid ee sanbabada sanka iyo sanbabada suufka oropharyngeal ee caabuqa Coronavirus ee cusub xaalado kale.


Faahfaahinta Alaabta

Tags Product

Magaca alaabta

HWTS-RT148-SARS-CoV-2/hargabka A/hargabka B Nucleic Acid Isku-dhafan Qalabka Garashada (Fluorescence PCR)

Kanaalka

Magaca Kanaalka PCR-Mix 1 PCR-Mix 2
FAM Channel ORF1ab hidde IVA
Kanaalka VIC/HEX Xakamaynta gudaha Xakamaynta gudaha
Kanaalka CY5 N hiddo-wadaha /
Kanaalka ROX E hidaha IVB

Qiyaasta Farsamada

Kaydinta

-18℃

Nolosha shelf 12 bilood
Nooca Tuunada Nasopharyngeal swabs iyo suufka oropharyngeal
Bartilmaameedka SARS-CoV-2 saddex bartilmaameed (Orf1ab, N iyo E hiddo-wadaha) / hargabka A / hargabka B
Ct ≤38
CV ≤10.0%
LoD SARS-CoV-2: 300 koobi/ml

Fayraska hargabka A: 500 koobi/mL

Fayraska hargabka B: 500 koobi/mL

Gaar ahaan a) Natiijooyinka tijaabada iskutallaabtu waxay muujisay in qalabku uu ku habboon yahay coronavirus bini'aadamka SARSr-CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, fayraska syncytial neef-mareenka A iyo B, fayraska parainfluenza 1, 2 iyo 3, rhinovirus, 3, 3, 3, 4, 3, 3, 3, 3, 3, 3, 3, 4, rhinovirus, iyo ade2virus. 5, 7 iyo 55, metapneumovirus aadanaha, enterovirus A, B, C iyo D, fayraska sambabada sambabada ee cytoplasmic, EB fayraska, fayraska jadeecada Human cytomegalovirus, rotavirus, norovirus, fayraska qaamo-qashiir, fayraska varicella zoster, Mycoplasma pneumoniae, Chlamydia, pneumoniae. hargabka, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, qaaxada Mycobacterium, Aspergillus fumigatus, Candida albicans, Candida glabrata Ma jirin falcelin u dhaxaysa Pneumocystis yersinioform iyo Cryptoans.

b) Awoodda ka hortagga faragelinta: dooro mucin (60mg/ml), 10% (V/V) dhiiga bini'aadamka, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (oo ka kooban preservative) (20mg/ml), beclomethasone (20mg/mL), dexamethasone (20mg/mL0), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), α-Interferon (800IU/ml), zanamivir (20mg/mL), ribavirin (10mg/mL), ribavirin (10mg/m. (1mg/mL), lopinavir (500mg/ml), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/ml), ceprotene (40μg/ml) Meropenem (200mg/ml), levofloxacin (10μg/mL) iyo levofloxacin (10μg/mL) Natiijooyinku waxay muujiyeen in walxaha faragelinta ee kor ku xusan aysan lahayn wax jawaab celin ah oo ku saabsan natiijooyinka ogaanshaha cudurada.

Qalabka lagu dabaqi karo Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah

Hababka noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah ee degdega ah

SLAN ®-96P Nidaamyada PCR-waqtiga-dhabta ah

QuantStudio™ 5 Nidaamyada PCR-waqtiga-dhabta ah

LightCycler®480 Nidaamka PCR-waqtiga dhabta ah

LineGene 9600 Plus-Waqtiga dhabta ah ee PCR Nidaamka ogaanshaha

MA-6000-waqtiga-dhabta ah ee cabbirka kulaylka wareegga

BioRad CFX96 Nidaamka PCR-waqtiga-dhabta ah

BioRad CFX Opus 96 Nidaamka PCR-waqtiga-dhabta ah

Wadarta Xalka PCR

socodka shaqada

  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir