SARS-CoV-2/hargabka A /hargabka B

Sharaxaad Gaaban:

Qalabkani wuxuu ku habboon yahay ogaanshaha tayada ee SARS-CoV-2, hargabka A iyo aashitada nukliyeerka ee influenza B ee suufka nasopharyngeal iyo muunadaha suufka ee afka kuwaas oo ka mid ah dadka looga shakisan yahay inay qabaan SARS-CoV-2, hargabka A iyo hargabka B. Waxa kale oo loo isticmaali karaa kiisaska looga shakisan yahay oofwareenka iyo kuwa looga shakisan yahay iyo ogaanshaha tayada iyo aqoonsashada SARS-CoV-2, hargabka A iyo aashitada nukliyeerka ee influenza B ee suufka nasopharyngeal iyo muunadaha suufka ee afka ee caabuqa cusub ee Coronavirus xaaladaha kale.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca alaabta

Qalabka Baaritaanka Isku-dhafan ee HWTS-RT148-SARS-CoV-2/influenza A /influenza B Nucleic Acid (Fluorescence PCR)

Kanaal

Magaca Kanaalka PCR-Mix 1 PCR-Mix 2
Kanaalka FAM Hidde-sidayaasha ORF1ab IVA
Kanaalka VIC/HEX Xakamaynta gudaha Xakamaynta gudaha
Kanaalka CY5 Hidde-side N /
Kanaalka ROX Jiin E IVB

Halbeegyada Farsamada

Kaydinta

-18℃

Muddada khaanadaha 12 bilood
Nooca Muunada suufka sanka iyo suufka afka
Bartilmaameed Saddex bartilmaameed oo SARS-CoV-2 ah ( hiddo-sideyaasha Orf1ab, N iyo E)/ hargabka A / hargabka B
Ct ≤38
CV ≤10.0%
LoD SARS-CoV-2:300 Nuqul/mL

Fayraska hargabka A: 500 Nuqul/mL

Fayraska hargabka B: 500 Nuqul/mL

Gaar ahaanshaha a) Natiijooyinka baaritaanka isdhaafka ah waxay muujiyeen in qalabku uu la jaanqaadi karo fayraska fayraska ee aadanaha (Human coronavirus SARSr-CoV), MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, fayraska isku-xidhka neefsashada ee A iyo B, fayraska parainfluenza 1, 2 iyo 3, rhinovirusA, B iyo C, adenovirus 1, 2, 3, 4, 5, 7 iyo 55, fayraska metapneumovirus-ka aadanaha, enterovirus A, B, C iyo D, fayraska sambabada ee aadanaha ee cytoplasmic, fayraska EB, fayraska jadeecada Fayraska cytomegalovirus-ka aadanaha, rotavirus, norovirus, fayraska mumps-ka, fayraska varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergillus fumigatus, Candida albicans, Candida glabrata Ma jirin wax falcelin isdhaafsi ah oo u dhexeeya Pneumocystis yersini iyo Cryptococcus neoformans.

b) Awoodda faragelinta ka hortagga: mucin-ka la xushay (60mg/mL), 10% (V/V) dhiigga aadanaha, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (oo ka kooban ilaaliye) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisone (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) iyo tobramycin (0.6mg/mL). Natiijooyinka waxay muujiyeen in walxaha farageliya ee ku jira xaddiga kor ku xusan aysan lahayn wax jawaab celin ah oo ku saabsan natiijooyinka ogaanshaha jeermiska.

Qalabka Khuseeya Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah

Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah

SLAN ®Nidaamyada PCR-ga Waqtiga-dhabta ah -96P

Nidaamyada PCR-ga ee QuantStudio™ 5-ta Waqti-dhabta ah

LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480

Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah

Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96

Xalka PCR ee Wadarta

socodka shaqada

  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir