28 Nooc oo Khatarta Sarreeysa ee Fayraska Papilloma Human (16/18 Qorista) Acid Nukliyeer ah

Sharaxaad Gaaban:

Qalabkani waxa uu ku haboon yahay ogaanshaha tayada fayraska ee 28 nooc oo ah fayrasyada papilloma virus (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) nucleic acid ee kaadida lab iyo dheddig iyo unugyo baxay ilmo galeenka.HPV 16/18 waa la qori karaa, noocyada soo haray si buuxda looma qori karo, taasoo bixisa hab caawiye oo lagu baaro iyo daawaynta caabuqa HPV.


Faahfaahinta Alaabta

Tags Product

Magaca alaabta

HWTS-CC006A-28 Noocyada Khatarta Sare leh ee Fayraska papilloma ee Aadanaha (16/18 Qorista) Qalabka lagu ogaado Acid Nukliyeer ah (Fluorescence PCR)

Epidemiology

Kansarka ilmo-galeenka waa mid ka mid ah burooyinka halista ah ee ugu badan ee marinka taranka dumarka.Daraasaduhu waxay muujiyeen in caabuqyada HPV ee joogtada ah iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo-galeenka.Waqtigan xaadirka ah, daawaynta waxtarka leh ee la aqoonsan yahay ayaa weli ka maqan kansarka ilmo-galeenka ee uu keeno HPV, sidaas darteed hore u ogaanta iyo ka-hortagga caabuqa ilmo-galeenka ee uu keeno HPV waa furaha ka hortagga kansarka ilmo-galeenka.Aad bay muhiim u tahay in la sameeyo baaritaan fudud, gaar ah oo degdeg ah oo ogaanshaha etiology ee ogaanshaha kiliinikada iyo daaweynta kansarka ilmo-galeenka.

Kanaalka

Isku darka falcelinta Kanaalka Nooca
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Xakamaynta Gudaha
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Xakamaynta Gudaha

Qiyaasaha Farsamada

Kaydinta Dareeraha: ≤-18℃
Nolosha shelf 12 bilood
Nooca Tuunada Xuubka afka ilmagaleenka, suufka siilka, kaadida
Ct ≤28
CV <5.0%
LoD 300 koobi/ml
Qalabka lagu dabaqi karo Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah
Nidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah ee degdegga ah
QuantStudio®5 Nidaamyada PCR-waqtiga-dhabta ah
SLAN-96P Nidaamyada PCR-waqtiga-dhabta ah
LightCycler®480 Nidaamka PCR-waqtiga dhabta ah
LineGene 9600 Plus-Waqtiga dhabta ah ee PCR Nidaamka ogaanshaha
MA-6000-waqtiga-dhabta ah ee cabbirka kulaylka wareegga
BioRad CFX96 Nidaamka PCR-waqtiga-dhabta ah
BioRad CFX Opus 96 Nidaamka PCR-waqtiga-dhabta ah

Socodka Shaqada

Soo saarista lagu taliyay: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaaso loo isticmaali karo Macro & Micro-Test Soo saarista Ashitada Nucleic Acid (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ku dar 200μL ee cusbada caadiga ah si aad dib ugu soo celiso pellet ee tallaabada 2.1, ka dibna soo saarista waa in lagu sameeyaa si waafaqsan Tilmaamaha isticmaalka reagent soo saarida.Mugga sare ee lagu taliyey waa 80μL.
Soo saarista lagu taliyay: QIAamp DNA Mini Kit (51304) ama Makro & Micro-Tijaabo Viral DNA/RNA Column (HWTS-3020-50).Ku dar 200μL oo cusbo ah oo caadi ah si aad dib ugu celiso pellet-ka tallaabada 2.1, ka dibna soo saarista waa in loo fuliyaa si waafaqsan tilmaamaha isticmaalka reagent soo saarista.Mugga muunada la soo saaray ee shaybaarada ayaa dhamaantood ah 200μL, mugga sare ee lagu taliyeyna waa 100μL.