28 Nooc oo Fayraska Papilloma-ga Aadanaha ee Khatarta Sare leh (Qoraalka 16/18) Nucleic Acid
Magaca alaabta
HWTS-CC006A-28 Noocyada Fayraska Papilloma-ga Aadanaha ee Khatarta Sare leh (Qoraalka 16/18) Qalabka Ogaanshaha Aashitada Nukliyeerka (Fluorescence PCR)
Cudurrada Faafa
Kansarka ilmo-galeenka waa mid ka mid ah burooyinka ugu badan ee ku dhaca habka taranka dumarka. Daraasaduhu waxay muujiyeen in caabuqyada joogtada ah ee HPV iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo-galeenka. Waqtigan xaadirka ah, daawaynta waxtarka leh ee la aqoonsan yahay weli ma jiraan kansarka ilmo-galeenka ee uu keeno HPV, sidaa darteed helitaanka hore iyo ka hortagga caabuqa ilmo-galeenka ee uu sababo HPV waa furaha ka hortagga kansarka ilmo-galeenka. Waa muhiimad weyn in la sameeyo baaritaan fudud, gaar ah oo degdeg ah oo lagu ogaanayo cudurka kansarka ilmo-galeenka si loo ogaado cudurka iyo daaweynta kansarka ilmo-galeenka.
Kanaal
| Isku-darka Falcelinta | Kanaal | Nooca |
| PCR-Mix1 | FAM | 18 |
| VIC (HEX) | 16 | |
| ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
| CY5 | Xakamaynta Gudaha | |
| PCR-Mix2 | FAM | 6, 11, 54, 83 |
| VIC (HEX) | 26, 44, 61, 81 | |
| ROX | 40, 42, 43, 53, 73, 82 | |
| CY5 | Xakamaynta Gudaha |
Halbeegyada Farsamada
| Kaydinta | Dareere: ≤-18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | Suunka Ilkaha, Suunka Siilka, Kaadida |
| Ct | ≤28 |
| CV | <5.0% |
| LoD | 300 Nuqullo/mL |
| Qalabka Khuseeya | Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480 Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000 Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96 Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96 |
Socodka Shaqada
Waxyaabaha lagu taliyay ee soo saarista: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ku dar 200μL oo cusbo caadi ah si aad dib ugu soo celiso pellet-ka tallaabada 2.1, ka dibna soo saarista waa in la sameeyaa iyadoo la raacayo tilmaamaha isticmaalka qalabkan soo saarista. Mugga soo saarista ee lagu taliyay waa 80μL.
Waxyaabaha lagu taliyay ee soo saarista: QIAamp DNA Mini Kit (51304) ama Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Ku dar 200μL oo cusbo caadi ah si aad dib ugu soo celiso pellet-ka tallaabada 2.1, ka dibna soo saarista waa in la sameeyaa iyadoo la raacayo tilmaamaha isticmaalka qalabkan soo saarista. Mugga muunadda ee la soo saaray ee muunadaha dhammaantood waa 200μL, mugga soo saarista ee lagu taliyayna waa 100μL.







