HPV 16 iyo HPV 18
Magaca alaabta
HWTS-CC001-Qalabka Baaritaanka Aashitada Nukliyeerka ee HPV16 iyo HPV18 (Fluorescence PCR)
Cudurrada Faafa
Kansarka ilmo-galeenka waa mid ka mid ah burooyinka ugu badan ee ku dhaca habka taranka dumarka. Waxaa la muujiyay in caabuqa HPV ee joogtada ah iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo-galeenka. Hadda waxaa weli jira la'aanta daaweyn wax ku ool ah oo guud ahaan la aqbalay oo loogu talagalay kansarka ilmo-galeenka oo uu keeno HPV. Sidaa darteed, ogaanshaha hore iyo ka hortagga caabuqa ilmo-galeenka ee uu sababo HPV waa furaha ka hortagga kansarka ilmo-galeenka. Sameynta baaritaanno fudud, gaar ah oo degdeg ah oo loogu talagalay cudurrada keena ayaa muhiimad weyn u leh ogaanshaha kiliinikada ee kansarka ilmo-galeenka.
Kanaal
| Kanaal | Nooca |
| FAM | HPV18 |
| VIC/HEX | HPV16 |
| CY5 | Xakamaynta Gudaha |
Halbeegyada Farsamada
| Kaydinta | ≤-18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | unugyada la jaray ee afka ilmo-galeenka |
| Ct | ≤28 |
| CV | ≤10.0% |
| LoD | 500 Nuqul/mL |
| Gaar ahaanshaha | Marka qalabka loo isticmaalo si loo tijaabiyo muunado aan gaar ahayn oo laga yaabo inay la falgalaan bartilmaameedyadooda, dhammaan natiijooyinka waa taban, oo ay ku jiraan Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mildew, Gardnerella iyo noocyada kale ee HPV ee aan ku jirin xirmada. |
| Qalabka Khuseeya | SLAN®Nidaamyada PCR-ga Waqtiga-dhabta ah -96PNidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480 Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer) Wareege kuleyl oo waqti-dhab ah oo MA-6000 ah. |
Socodka Shaqada
Ikhtiyaar 1.
Wakiilka Sii-deynta Muunadda Macro & Micro-Test (HWTS-3005-8), waa in laga soo saaraa iyadoo la raacayo tilmaamaha.
Ikhtiyaar 2.
Qalabka Guud ee Baaritaanka Macro & Micro-Test DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) iyo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS-3006C), waa in la soo saaraa iyadoo la raacayo tilmaamaha. Mugga muunadda la soo saaray waa 200μL, mugga dheecaanka lagu taliyayna waa 80µL.
Ikhtiyaar 3.
Qalabka yar ee DNA-da ee QIAamp (51304) oo ay soo saartay QIAGEN ama Qalabka DNA/RNA ee TIAnamp Virus (YDP315) oo ay soo saartay Tiangen Biotech (Beijing) Co., Ltd., waa in si adag loo soo saaraa iyadoo la raacayo tilmaamaha. Mugga muunadda la soo saaray waa 200μL, mugga dheecaanka lagu taliyayna waa 80µL.