HPV16 iyo HPV18

Sharaxaad Gaaban:

Qalabkani waa intended loogu talagalay ogaanshaha tayada in vitro ee jajabyada nucleic acid ee gaarka ah ee papillomavirus (HPV) 16 iyo HPV18 ee unugyada ilmagaleenka dheddigga ah.


Faahfaahinta Alaabta

Tags Product

Magaca alaabta

HWTS-CC001-HPV16 iyo HPV18 Qalabka Ogaanshaha Ashitada Nukliyeerka (Fluorescence PCR)

Epidemiology

Kansarka ilmo-galeenka waa mid ka mid ah burooyinka halista ah ee ugu badan ee ku dhaca habka taranka haweenka.Waxaa la muujiyay in caabuqa HPV ee joogtada ah iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo galeenka.Waqtigan xaadirka ah waxaa jira la'aanta daaweyn wax ku ool ah oo guud ahaan la aqbalay oo loogu talagalay kansarka ilmo-galeenka ee uu keeno HPV.Sidaa darteed, ogaanshaha hore iyo ka hortagga caabuqa afka ilmo-galeenka ee uu keeno HPV waa furayaasha ka hortagga kansarka ilmo-galeenka.Sameynta baaritaanno fudud, gaar ah oo degdeg ah oo lagu ogaanayo cudur-sidaha ayaa muhiimad weyn u leh ogaanshaha bukaan-socodka ee kansarka ilmo-galeenka.

Kanaalka

Kanaalka Nooca
FAM HPV18
VIC/HEX HPV16
CY5

Xakamaynta Gudaha

Qiyaasaha Farsamada

Kaydinta

≤-18℃

Nolosha shelf 12 bilood
Nooca Tuunada unugga exfoliated afka ilmagaleenka
Ct ≤28
CV ≤10.0%
LoD 500 koobi/ml
Gaar ahaan Markaad isticmaasho qalabka si aad u tijaabiso shay-baarayaal aan gaar ahayn oo laga yaabo inay ka falceliyaan yoolalka, dhammaan natiijooyinka waa taban, oo ay ku jiraan Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mildew, Gardnerella oo aan daboolin noocyada kale ee HPV xirmada.
Qalabka lagu dabaqi karo SLAN®-96P Nidaamyada PCR-waqtiga-dhabta ahNidaamyada noolaha ee la dabaqay 7500 Nidaamyada PCR-waqtiga-dhabta ah

QuantStudio®5 Nidaamyada PCR-waqtiga-dhabta ah

LightCycler®480 Nidaamka PCR-waqtiga dhabta ah

Nidaamka ogaanshaha PCR ee LineGene 9600 Plus-waqtiga-dhabta ah (FQD-96A, farsamada Hangzhou Bioer)

MA-6000-waqtiga-dhabta ah ee cabbirka kulaylka wareegga.

Socodka Shaqada

Ikhtiyaarka1.

Macro & Micro-Test Tusaalaha Siideynta Reagent (HWTS-3005-8), waa in lagu soo saaraa si waafaqsan tilmaamaha.

Ikhtiyaarka2.

Qalabka Makro & Micro-Tijaabada Guud ee DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) HWTS-3006C), waa in la soo saaraa si waafaqsan tilmaamaha.Mugga muunadda la soo saaray waa 200μL, mugga sareynta lagu taliyeyna waa 80µL.

Ikhtiyaarka3.

QIAamp DNA Mini Kit (51304) oo ay soo saartay QIAGEN ama TIANAmp Virus DNA/RNA Kit (YDP315) oo ay samaysay Tiangen Biotech (Beijing) Co., Ltd., waa in si adag loo soo saaro si waafaqsan tilmaamaha.Mugga muunadda la soo saaray waa 200μL, mugga sareynta lagu taliyeyna waa 80µL.


  • Hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir