Tijaabada degdega ah ee unugyada unugyada - Easy Amp

Sharaxaad Gaaban:

Ku habboon alaabta ogaanshaha heerkulka joogtada ah ee xoojinta reagents ee falcelinta, falanqaynta natiijada, iyo soosaarka natiijada.Ku haboon ogaanshaha falcelinta degdega ah, ogaanshaha degdega ah ee goobaha aan shaybaadhka ahayn, cabbir yar, fududahay in la qaado.


Faahfaahinta Alaabta

Tags Product

Heerka dahabka ee ogaanshaha aashitada nucleic

Ku habboon · La qaadi karo

Nidaamka kormeerka heerkulbeegga

Madal molecular

Tijaabada degdega ah

Magaca alaabta

Fudud Amp-waqtiga-dhabta ah Nidaamka ogaanshaha Fluorescence Isothermal

Shahaado

CE, FDA, NMPA

Madal tignoolajiyada

Kordhinta Enzymatic Probe Isothermal

Astaamaha

Degdeg ah Muunad togan: 5 daqiiqo gudahood
Muuqda Muujinta waqtiga-dhabta ah ee natiijooyinka ogaanshaha
Fudud 4x4 naqshadaynta moduleka kuleylka madaxa banaan waxay u oggolaaneysaa ogaanshaha muunadda dalabka
Tamar hufan Waxaa la dhimay 2/3 marka la barbar dhigo farsamooyinka dhaqameed
La qaadi karo Xajmi yar, fudud in la qaado, daboolo baahiyaha tijaabada ee deegaanka aan shaybaadhka ahayn
Sax ah Ogaanshaha tirada ayaa leh shaqo is-habayn waxayna soo saartaa natiijooyinka ogaanshaha tirada

Meelaha lagu dabaqi karo

Madaarka

Madaarka, Kastamka, Doomaha, Bulshada (Teendhada), Rugaha Caafimaadka Yaryar, Shaybaarka Imtixaanka Wareega, Cisbitaalka, iwm.

Qiyaasaha Farsamada

Qaabka HWTS 1600S HWTS 1600P
Kanaalka fluorescent FAM, ROX FAM, ROX, VIC, CY5
Madal lagu ogaanayo Kordhinta Enzymatic Probe Isothermal
Awood 4 si fiican × 200μL × 4 kooxaha
Tusaalaha mugga 20-60μL
Kala duwanaanta heerkulka 35 ~ 90 ℃
Saxnaanta heerkulka ≤±0.5℃
Isha iftiinka kicinta Iftiiminta sare ee LED
Printer Tignoolajiyada kulaylka daabacaadda degdega ah
Kuleylinta Semiconductor Xawaaraha degdega ah, ilaalinta kulaylka deggan
Heerkulka kaydinta -20 ℃ ~ 55 ℃
Cabirka 290mm×245mm×128mm
Miisaanka 3.5KG

Socodka Shaqada

Gegida dayuuradaha1

Reagent

Caabuqa habdhiska neefsiga SARS-CoV-2, Hargabka A, Hargabka B, Qaaxada Mycobacterium, HRSVa, HRSVb, HRV, HPIV1, HPIV2, HPIV3
Cudurada faafa Plasmodium, dengue
Caafimaadka taranka Kooxda B Streptococcus, NG, UU, MH, MG
Cudurada mindhicirka Enterovirus, Candida Albicans
Haddii kale Zaire, Reston, Suudaan

Easy Amp VS PCR-waqtiga dhabta ah

  Amp fudud PCR-waqtiga dhabta ah
Natiijada ogaanshaha Muunad togan: 5 daqiiqo gudahood 120 daqiiqo
Waqtiga kordhinta 30-60 daqiiqo 120 daqiiqo
Habka kordhinta Kordhinta Isothermal Kordhinta heerkulka kala duwan
Meelaha lagu dabaqi karo Ma jiraan shuruudo gaar ah Kaliya PCR Lab
Natiijada natiijada Tignoolajiyada kulaylka daabacaadda degdega ah Nuqul USB ah, oo uu daabacay daabace

  • Hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir

    Qaybaha alaabta