Chlamydia Trachomatis Nucleic Acid
Magaca Badeecada
Qalabka Baaritaanka Aashitada Nukliyeerka ee HWTS-UR001A-Chlamydia Trachomatis (PCR-ga Fluorescence)
Isticmaalka Loogu Talogalay
Qalabkan waxaa loo isticmaalaa in lagu ogaado tayada Chlamydia trachomatis nucleic acid ee kaadida ragga, suufka kaadi mareenka ragga, iyo muunadaha suufka afka ilmo-galeenka dumarka.
Cudurrada Faafa
Chlamydia trachomatis (CT) waa nooc ka mid ah noolaha prokaryotic-ga ah oo si adag ugu dulinsan unugyada eukaryotic-ga. Chlamydia trachomatis waxa loo qaybiyaa noocyada AK iyadoo loo eegayo habka serotype-ka. Caabuqyada marinnada kaadi mareenka waxaa inta badan sababa noocyada kala duwan ee trachoma ee bayoolojiga DK, raggana waxaa badanaa loo muujiyaa inay yihiin urethritis, kaas oo la daweyn karo iyada oo aan la daaweyn, laakiin intooda badan waxay noqdaan kuwo daba-dheeraada, marmarna ka sii dara, waxaana lagu dari karaa epididymitis, proctitis, iwm. Dheddigga waxaa sababi kara urethritis, cervicitis, iwm., iyo dhibaatooyin aad u daran oo ka dhasha salpingitis.
Cudurrada Faafa
FAM: Chlamydia trachomatis (CT) ·
VIC(HEX): Xakamaynta Gudaha
Dejinta Xaaladaha Kordhinta PCR
| Tallaabo | Wareegyo | Heerkulka | Waqtiga | Ururi Calaamadaha Iftiiminta iyo Maya |
| 1 | 1 wareeg | 50℃ | 5 daqiiqo | No |
| 2 | 1 wareeg | 95℃ | 10 daqiiqo | No |
| 3 | 40 wareeg | 95℃ | 15 ilbiriqsi | No |
| 4 | 58℃ | 31 ilbiriqsi | Haa |
Halbeegyada Farsamada
| Kaydinta | ≤-18℃ Mugdi ku jira |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | Dheecaanka kaadi mareenka ragga, Dheecaanka afka ilmo-galeenka dumarka, Kaadida ragga |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 400 Nuqullo/mL |
| Gaar ahaanshaha | Ma jiro wax fal-celin isdhaafsi ah oo lagu ogaan karo jeermisyada kale ee qaba STD-yada qalabkan, sida Treponema pallidum, Neisseria gonorrhoeae, Ureaplasma urealyticum, Mycoplasma hominis, Mycoplasma genitalium, iwm., kuwaas oo ka baxsan heerka ogaanshaha qalabka. |
| Qalabka Khuseeya | Waxay la mid noqon kartaa qalabka PCR-ka ee caadiga ah ee suuqa yaalla. Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P LightCycler®Nidaamka PCR-ga ee Waqtiga-dhabta ah ee 480 Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000 Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96 Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96 |