Qalabka Ogaanshaha Aashitada Nucleic ee Ureaplasma (PCR-ga Fluorescence)

Sharaxaad Gaaban:

Qalabkani wuxuu ku habboon yahay ogaanshaha tayada ee Ureaplasma urealyticum (UU) ee kaadi mareenka ragga iyo muunadaha dheecaanka xubinta taranka dumarka ee in vitro.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca Badeecada

Qalabka Ogaanshaha Aashitada Nucleic ee Ureaplasma (PCR-ga Fluorescence)

Cudurrada Faafa

Ureaplasma urealyticum (UU) waa noolaha ugu yar ee prokaryotic-ga ah ee si madax-bannaan ugu noolaan kara bakteeriyada iyo fayrasyada, waana noole yar oo cudur keena oo u nugul caabuqyada xubnaha taranka iyo kaadi mareenka. Ragga, waxay sababi kartaa prostatitis, urethritis, pyelonephritis, iwm. Dumarka, waxay sababi kartaa falcelin barar ah oo ku dhaca habka taranka sida vaginitis, cervicitis, iyo cudurka bararka miskaha. Waa mid ka mid ah cudurada keena dhalmo la'aanta iyo ilmo soo rididda. Ureaplasma urealyticum waxay u qaybsan tahay 14 nooc oo serotypes ah, kuwaas oo loo qaybiyay laba kooxood iyadoo loo eegayo astaamaha bayoolojiga ee molecular: kooxda bayoolojiga Ⅰ (Up) iyo kooxda bayoolojiga Ⅱ (Uu). Kooxda bayoolojiga 1 waxay ka kooban tahay 4 nooc oo serotypes ah oo leh genome yar yar (1, 3, 6, iyo 14); kooxda bayoolojiga II waxay ka kooban tahay 10ka nooc ee soo haray oo leh genome waaweyn.

Kanaal

FAM Aashitada Nukliyeerka UU
VIC (HEX) Xakamaynta Gudaha

Halbeegyada Farsamada

Kaydinta Dareere ah:≤-18℃ Mugdi ku jira
Muddada khaanadaha 12 bilood
Nooca Muunada Kaadida labka, suufka kaadi mareenka labka, suufka afka ilmo-galeenka dheddigga
Ct ≤38
CV ≤5.0%
LoD 50 Nuqullo/falcelin
Gaar ahaanshaha Ma jiro wax falcelin isdhaafsi ah oo lala sameeyo jeermisyada kale ee caabuqa STD-ga ee ka baxsan heerka ogaanshaha qalabka, sida Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, herpes simplex virus nooca 1, iyo herpes simplex virus nooca.
Qalabka Khuseeya Waxay la mid noqon kartaa qalabka PCR-ka ee caadiga ah ee suuqa yaalla.Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ahNidaamyada PCR-ga ee QuantStudio® 5-ta Waqti-dhabta ah

Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P

Nidaamka PCR-ga ee waqtiga-dhabta ah ee LightCycler®480

Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah

Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000

Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96

Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96

Socodka Shaqada

Qalabka Ogaanshaha Aashitada Nucleic ee Ureaplasma (PCR-ga Fluorescence)

Reagent-yadu waxay u baahan yihiin laakiin lama bixin

Wakiilka Soo-saarista Muunadda Macro & Micro-Test (HWTS-3005-8), Qalabka DNA/RNA ee Viral ee Macro & Micro-Test (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Xalka ilaalinta kaadida ee cusbada caadiga ah.

Qalabka la isticmaalo waa loo baahan yahay laakiin lama bixin

1.5mL oo ah tuubo centrifuge ah oo aan lahayn DNase/RNase, Tips aan lahayn DNase/RNase, ethanol aan biyo lahayn, pipette, centrifuge-ka miiska, isku-darka kursiga keydka