Qalabka Ogaanshaha Aashitada Nukliyeerka ee Mycoplasma Hominis (PCR-ka Fluorescence)
Magaca alaabta
Qalabka Ogaanshaha Aashitada Nukliyeerka ee Mycoplasma Hominis (PCR-ka Fluorescence)
Cudurrada Faafa
Cudurrada galmada lagu kala qaado (STDs) ayaa weli ah mid ka mid ah khataraha muhiimka ah ee amniga caafimaadka dadweynaha adduunka, kuwaas oo keeni kara dhalmo la'aan, dhalmo uurjiif ah oo dhicis ah, burooyinka iyo dhibaatooyin kala duwan oo halis ah. Mycoplasma hominis waxay ku jirtaa marinnada taranka waxayna sababi kartaa falcelin barar ah marinnada taranka. Caabuqa MH ee marinnada taranka wuxuu sababi karaa cudurro sida urethritis-ka aan gonococcal ahayn, epididymitis, iwm., iyo dumarka dhexdooda, kuwaas oo sababi kara caabuq ku dhaca habdhiska taranka ee ku faafa xudunta ilmo-galeenka. Isla mar ahaantaana, dhibaatada caadiga ah ee caabuqa MH waa salpingitis, tiro yar oo bukaan ah ayaa laga yaabaa inay yeeshaan endometritis iyo cudur bararka miskaha.
Kanaal
| FAM | Bartilmaameedka MH |
| VIC (HEX) | Xakamaynta Gudaha |
Halbeegyada Farsamada
| Kaydinta | Dareere: ≤-18℃ Mugdi ku jira |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | dheecaanka kaadi mareenka, dheecaanka afka ilmo-galeenka |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 1000 Nuqullo/mL |
| Gaar ahaanshaha | Ma jiro fal-celin isdhaafsi ah oo lala sameeyo jeermisyada kale ee caabuqa STD-ga, kuwaas oo ka baxsan heerka ogaanshaha, mana jiro fal-celin isdhaafsi ah oo lala yeesho chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus nooca 1, herpes simplex virus nooca 2, iwm. |
| Qalabka Khuseeya | Waxay la mid noqon kartaa qalabka PCR-ka ee caadiga ah ee suuqa yaalla. Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga ee Waqtiga-dhabta ah ee Degdegga ah Nidaamyada PCR-ga ee waqtiga-dhabta ah ee QuantStudio®5 Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P Nidaamka PCR-ga ee waqtiga-dhabta ah ee LightCycler®480 Nidaamka Ogaanshaha PCR-ga ee LineGene 9600 Plus ee Waqtiga-dhabta ah Wareegga Kulaylka Tirada-Waqtiga-dhabta ah ee MA-6000 Nidaamka PCR-ga ee Waqtiga-dhabta ah ee BioRad CFX96 Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96 |
Socodka Shaqada
Reagent-yadu waxay u baahan yihiin laakiin lama bixin
Wakiilka Soo-saarista Muunadda ee Macro & Micro-Test (HWTS-3005-8), Qalabka DNA/RNA ee Viral ee Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) iyo Macro & Micro-Test Soo-saarayaasha Aashitada Nucleic ee Tooska ah (HWTS-3006C, HWTS-3006B). Qalabka Soo-saarista Aashitada Nucleic ama Nadiifinta (YDP302) oo ka socda Tiangen Biotech (Beijing) Co., Ltd.
Qalabka la isticmaalo waa loo baahan yahay laakiin lama bixin
1.5mL oo ah tuubada centrifuge-ka ee aan RNase/DNase lahayn, tip-yada aan RNase/DNase lahayn, ethanol-ka oo dhammaystiran, pipette-ka, centrifuge-ka desktop-ka, isku-darka mixer-ka desktop-ka.