Qalabka Ogaanshaha STI Multiplex 7

Sharaxaad Gaaban:

Koodhka Badeecada

HWTS-UR012

Isticmaalka Loogu Talogalay

Qalabkan waxaa loogu talagalay in lagu ogaado tayada cudurada caadiga ah ee caabuqyada kaadi mareenka, oo ay ku jiraan Neisseria gonorrhoeae (NG), Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), Herpes Simplex Virus Type 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), Mycoplasma hominis (Mh), Mycoplasma genitalium (Mg) ee kaadi mareenka ragga iyo muunadaha dheecaanka xubinta taranka dumarka.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Magaca Badeecada

Qalabka Ogaanshaha Cudurrada Isku-dhafan ee STI

Cudurrada Faafa

Caabuqyada galmada lagu kala qaado (STI) ayaa weli ah mid ka mid ah khataraha ugu waaweyn ee amniga caafimaadka dadweynaha adduunka, kuwaas oo horseedi kara dhalmo la'aan, dhalmada kahor, burooyinka, iyo dhibaatooyin kala duwan oo halis ah. Waxaa jira noocyo badan oo ah jeermisyada galmada lagu kala qaado, oo ay ku jiraan bakteeriyada, fayrasyada, chlamydia, mycoplasma, iyo spirochetes. NG, CT, UU, HSV 1, HSV 2, Mh, Mg ayaa aad ugu badan.

Halbeegyada Farsamada

Kaydinta ≤ -18℃
Muddada khaanadaha 12 bilood
Nooca Muunada Dheecaanka kaadi mareenka, Dheecaanka afka ilmo-galeenka
CV <5.0%
LoD Xadka Ogaanshaha (LoD): LoD-ga qalabka lagu ogaanayo CT, NG, UU, HSV1, HSV2 iyo Mg waa 400 Nuqul/mL; LoD-ga qalabka lagu ogaanayo Mh waa 1000 Nuqul/mL.
Gaar ahaanshaha Ma jiro wax falcelin isdhaafsi ah oo lala yeesho jeermisyada STI ee la midka ah.
Qalabka Khuseeya

Nidaamyada PCR-ka ee La Adeegsaday ee Biosystems 7500 Real-Time, Nidaamyada PCR-ka ee La Adeegsaday ee Biosystems 7500 Fast-Real-Time, Nidaamyada PCR-ka ee QuantStudio®5 Real-Time, Nidaamyada PCR-ka ee SLAN® -96P Real-Time, Nidaamka PCR-ka ee LightCycler® 480 Real-Time, Nidaamka Ogaanshaha PCR-ka ee LineGene 9600 Plus Real-Time (FQD-96A, Tiknoolajiyadda Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), BioRad CFX96 Real-Time PCR System, BioRad CFX Opus 96 Real-Time PCR System iyo iwm.

Kanaal

Kaydka Falcelinta Bartilmaameed Weriyaha Dab-damiye
Kaydka Falcelinta STI 1 CT FAM midna
UU VIC (HEX) midna
Mh ROX midna
HSV1 CY5 midna
Kaydka Falcelinta STI 2 NG FAM midna
HSV2 VIC (HEX) midna
Mg ROX midna
IC CY5 midna

Socodka Shaqada

670e945511776ae647729effe7ec6fa

Reagent-yadu waxay u baahan yihiin laakiin lama bixin

Wakiilka Soo-saarista Muunadda Macro & Micro-Test (HWTS-3005-8); Qalabka Guud ee Baaritaanka Macro & Micro-Test DNA/RNA (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Soo-saarista waa in loo sameeyaa iyadoo loo eegayo IFU.

Qalabka la isticmaalo waa loo baahan yahay laakiin lama bixin:1.5mL oo ah tuubada centrifuge-ka ee aan lahayn DNase/RNase, Talooyin aan lahayn DNase/RNase, entrifuge-ka desktop-ka, isku-darka oscillation-ka desktop-ka.


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir