Qalabka Ogaanshaha STI Multiplex 7
Magaca Badeecada
Qalabka Ogaanshaha Cudurrada Isku-dhafan ee STI
Cudurrada Faafa
Caabuqyada galmada lagu kala qaado (STI) ayaa weli ah mid ka mid ah khataraha ugu waaweyn ee amniga caafimaadka dadweynaha adduunka, kuwaas oo horseedi kara dhalmo la'aan, dhalmada kahor, burooyinka, iyo dhibaatooyin kala duwan oo halis ah. Waxaa jira noocyo badan oo ah jeermisyada galmada lagu kala qaado, oo ay ku jiraan bakteeriyada, fayrasyada, chlamydia, mycoplasma, iyo spirochetes. NG, CT, UU, HSV 1, HSV 2, Mh, Mg ayaa aad ugu badan.
Halbeegyada Farsamada
| Kaydinta | ≤ -18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | Dheecaanka kaadi mareenka, Dheecaanka afka ilmo-galeenka |
| CV | <5.0% |
| LoD | Xadka Ogaanshaha (LoD): LoD-ga qalabka lagu ogaanayo CT, NG, UU, HSV1, HSV2 iyo Mg waa 400 Nuqul/mL; LoD-ga qalabka lagu ogaanayo Mh waa 1000 Nuqul/mL. |
| Gaar ahaanshaha | Ma jiro wax falcelin isdhaafsi ah oo lala yeesho jeermisyada STI ee la midka ah. |
| Qalabka Khuseeya | Nidaamyada PCR-ka ee La Adeegsaday ee Biosystems 7500 Real-Time, Nidaamyada PCR-ka ee La Adeegsaday ee Biosystems 7500 Fast-Real-Time, Nidaamyada PCR-ka ee QuantStudio®5 Real-Time, Nidaamyada PCR-ka ee SLAN® -96P Real-Time, Nidaamka PCR-ka ee LightCycler® 480 Real-Time, Nidaamka Ogaanshaha PCR-ka ee LineGene 9600 Plus Real-Time (FQD-96A, Tiknoolajiyadda Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), BioRad CFX96 Real-Time PCR System, BioRad CFX Opus 96 Real-Time PCR System iyo iwm. |
Kanaal
| Kaydka Falcelinta | Bartilmaameed | Weriyaha | Dab-damiye |
| Kaydka Falcelinta STI 1 | CT | FAM | midna |
| UU | VIC (HEX) | midna | |
| Mh | ROX | midna | |
| HSV1 | CY5 | midna | |
| Kaydka Falcelinta STI 2 | NG | FAM | midna |
| HSV2 | VIC (HEX) | midna | |
| Mg | ROX | midna | |
| IC | CY5 | midna |
Reagent-yadu waxay u baahan yihiin laakiin lama bixin
Wakiilka Soo-saarista Muunadda Macro & Micro-Test (HWTS-3005-8); Qalabka Guud ee Baaritaanka Macro & Micro-Test DNA/RNA (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Soo-saarista waa in loo sameeyaa iyadoo loo eegayo IFU.
Qalabka la isticmaalo waa loo baahan yahay laakiin lama bixin:1.5mL oo ah tuubada centrifuge-ka ee aan lahayn DNase/RNase, Talooyin aan lahayn DNase/RNase, entrifuge-ka desktop-ka, isku-darka oscillation-ka desktop-ka.