Mycoplasma hominis, Ureaplasma urealyticum iyo Gardnerella vaginalis nucleic acid
Magaca alaabta
HWTS-UR044-Mycoplasma hominis, Ureaplasma urealyticum iyo Gardnerella vaginalis Nucleic Acid Observation Kit (Fluorescence PCR)
Cudurrada Faafa
Mycoplasma hominis (MH) waa nooc ka mid ah mycoplasma oo ka jira marinnada kaadida iyo xubnaha taranka, waxayna sababi kartaa caabuqyada kaadi mareenka iyo bararka xubnaha taranka. Mycoplasma hominis si weyn ayuu ugu jiraa dabiiciga, waxaana lala xiriiriyaa noocyo kala duwan oo caabuqyada xubnaha taranka sida urethritis nongonococcal, cervicitis-ka dumarka, adnexitis, dhalmo la'aan, iwm. Ureaplasma urealyticum (UU) waa noolaha ugu yar ee unugyada prokaryotic-ga ee u dhexeeya bakteeriyada iyo fayrasyada, waana noole si madax-bannaan u noolaan kara, waana noole yar oo cudur keena oo si fudud u keena caabuqyada mareenka taranka iyo kaadi mareenka. Ragga, waxay sababi kartaa prostatitis, urethritis, pyelonephritis, iwm.; haweenka, waxay sababi kartaa falcelin barar ah oo ku dhaca marinnada taranka sida vaginitis, cervicitis, iyo cudurka bararka miskaha, waana mid ka mid ah cudurada keena dhalmo la'aanta iyo dhicisnimada. Sababta ugu badan ee keenta vaginitis-ka dumarka waa vaginosis-ka bakteeriyada, bakteeriyada muhiimka ah ee bakteeriyada vaginosis-kana waa Gardnerella vaginalis. Gardnerella vaginalis (GV) waa cudur faafa oo aan keenin cudur marka uu tiro yar ku jiro. Si kastaba ha ahaatee, marka bakteeriyada ugu badan ee siilka ee Lactobacilli la yareeyo ama la baabi'iyo, taasoo keenta dheelitir la'aan ku timaada deegaanka siilka, Gardnerella vaginalis waxay ku tarmaan tiro badan, taasoo keenta vaginosis bakteeriyada. Isla mar ahaantaana, cudurro kale (sida Candida, Neisseria gonorrhoeae, Mycoplasma hominis, iwm.) waxay u badan tahay inay soo galaan jirka aadanaha, taasoo keenta vaginitis isku dhafan iyo cervicitis. Haddii vaginitis iyo cervicitis aan la ogaan oo aan si waqtiyeysan oo wax ku ool ah loo daaweyn, waxaa jiri kara caabuqyo ay keenaan jeermisyada ku dhaca xuubka taranka, taasoo si fudud u horseedi karta caabuqyada sare ee taranka sida endometritis, salpingitis, tubo-ovarian abscess (TOA), iyo peritonitis miskaha, taasoo keeni karta dhibaatooyin halis ah sida dhalmo la'aan, uurka ectopic iyo xitaa natiijooyinka uurka ee xun.
Halbeegyada Farsamada
| Kaydinta | ≤-18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | suufka kaadi mareenka ragga, suufka afka ilmo-galeenka dumarka, suufka siilka dumarka |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | UU, GV 400 Nuqullo/mL; MH 1000 Nuqullo/mL |
| Qalabka Khuseeya | Waxaa lagu dabaqi karaa nooca I ee wax soo saarka ogaanshaha: Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah, QuantStudio®5 Nidaam oo PCR-Waqtiga-dhabta ah, Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.), Nidaamyada Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer), Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.), Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX96, Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96. Waxaa lagu dabaqi karaa nooca II ee wax soo saarka ogaanshaha: EudemonTMAIO800 (HWTS-EQ007) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Socodka Shaqada
Qalabka DNA/RNA ee Viral ee Macro & Micro-Test (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), iyo Qalabka DNA/RNA ee Macro & Micro-Test Viral (HWTS-3017-8) (kaas oo loo isticmaali karo Eudemon)TM AIO800 (HWTS-EQ007)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Mugga muunadda la soo saaray waa 200μL mugga dheecaanka lagu taliyayna waa 150μL.







