Herpes-ka xubinta taranka waa cudur caadi ah oo galmada lagu kala qaado oo uu keeno HSV2, kaasoo aad u faafa. Sannadihii ugu dambeeyay, dhacdooyinka herpes-ka xubinta taranka ayaa si weyn u kordhay, iyadoo ay ugu wacan tahay kororka dhaqamada galmada ee khatarta ah, heerka ogaanshaha HSV1 ee herpes-ka xubinta taranka ayaa kordhay waxaana la sheegay inuu gaarayo 20%-30%. Caabuqa bilowga ah ee fayraska herpes-ka xubinta taranka badanaa waa aamusan yahay iyada oo aan lahayn calaamado caafimaad oo muuqda marka laga reebo herpes-ka maxalliga ah ee xuubka ama maqaarka ee dhowr bukaan. Maadaama herpes-ka xubinta taranka lagu garto daadinta fayraska cimriga oo dhan iyo u janjeersiga soo noqoshada, waa muhiim in la baaro jeermiska sida ugu dhakhsaha badan oo loo xakameeyo gudbinta.
Halbeegyada Farsamada
| Kaydinta | -18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | suufka kaadi mareenka ragga, suufka afka ilmo-galeenka dumarka, suufka siilka dumarka |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 400Nuqullo/mL |
| Qalabka Khuseeya | Waxaa lagu dabaqi karaa nooca I ee wax soo saarka ogaanshaha: Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah, Nidaamyada PCR-ga ee waqtiga-dhabta ah ee QuantStudio®5, Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.), Nidaamyada Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer), Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.), Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX96, Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96. Waxaa lagu dabaqi karaa nooca II ee wax soo saarka ogaanshaha: EudemonTMAIO800 (HWTS-EQ007) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Socodka Shaqada
Reagent-yada ayaa loo baahan yahay laakiin lama bixin
Qalabka Guud ee Baaritaanka Macro & Micro-Test DNA/RNA (HWTS-3019) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Agabka loo baahan yahay laakiin lama bixin
Tuubooyinka centrifuge-ka ee aan lahayn DNase/RNase 1.5 mL, tips-ka aan lahayn DNase/RNase, ethanol-ka oo dhammaystiran, pipettor, centrifuge-ka benchtop, isku-darka vortex-ka benchtop.