Qalabka Ogaanshaha Aashitada Nukliyeerka ee Treponema Pallidum
Magaca alaabta
Qalabka Ogaanshaha Aashitada Nukliyeerka ee Treponema Pallidum
Cudurrada Faafa
Noocyada Ureaplasma ee hadda la xiriira cudurka aadanaha waxay u qaybsan yihiin 2 kooxood oo noole ah iyo 14 nooc oo serotypes ah. Kooxda noole Ⅰ waa Ureaplasma urealyticum, oo ay ku jiraan noocyada serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, iyo 13. Kooxda noole Ⅱ waa Ureaplasma parvum, oo ay ku jiraan noocyada serotypes: 1, 3, 6, 14. Ureaplasma waa dulin ama dulin caadi ah oo ku jira habka taranka hoose ee dheddigga waana mid ka mid ah cudurada muhiimka ah ee keena cudurada faafa ee nidaamka taranka. Marka laga soo tago inay keenaan caabuqyada marinnada taranka, haweenka qaba caabuqa Ureaplasma waxay sidoo kale aad ugu badan yihiin inay u gudbiyaan cudurka lammaanahooda galmada. Caabuqa Ureaplasma sidoo kale waa mid ka mid ah sababaha muhiimka ah ee dhalmo la'aanta. Haddii haweenka uurka leh ay qaadaan Ureaplasma, waxay sidoo kale keeni kartaa dillaac degdeg ah oo xuubka ah, dhalmada kahor, cilladda neefsashada ee dhallaanka, caabuqa dhalmada kadib iyo cawaaqib xumo kale oo uur ah, kuwaas oo u baahan fiiro gaar ah.
Halbeegyada Farsamada
| Kaydinta | -18℃ |
| Muddada khaanadaha | 12 bilood |
| Nooca Muunada | kaadi mareenka ragga, habka taranka dumarka |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 400 Nuqul/mL |
| Qalabka Khuseeya | Waxaa lagu dabaqi karaa nooca I ee wax soo saarka ogaanshaha: Nidaamyada Bayoolajiga ee La Adeegsaday 7500 Nidaamyada PCR-ga Waqtiga-dhabta ah, QuantStudio®5 Nidaamyada PCR-ga Waqtiga-dhabta ah, Nidaamyada PCR-ga Waqtiga-dhabta ah ee SLAN-96P (Hongshi Medical Technology Co., Ltd.), Nidaamyada Ogaanshaha PCR-ga ee LineGene 9600 Plus (FQD-96A, tignoolajiyada Hangzhou Bioer), Wareege Kulayl oo Waqtiga-dhabta ah MA-6000 (Suzhou Molarray Co., Ltd.), Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX96, Nidaamka PCR-ga ee waqtiga-dhabta ah ee BioRad CFX Opus 96. Waxaa lagu dabaqi karaa nooca II ee wax soo saarka ogaanshaha: EudemonTMAIO800 (HWTS-EQ007) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Socodka Shaqada
Wakiilka Reagent-ka waa loo baahan yahay laakiin lama bixin
Qalabka Saline-ka Caadiga ah, Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (kaas oo loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) oo ay samaysay Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Alaabta la isticmaalo waa loo baahan yahay laakiin lama bixin
Talooyin aan RNase/DNase lahayn, tuubooyin centrifuge ah oo aan 1.5 mL lahayn oo RNase/DNase lahayn, centrifuge-ka desktop-ka, Isku-darka vortex






-300x186.png)
