14 Noocyada Khatarta Sarreeysa ee Fayraska Papillomavirus (16/18/52 Qorista)
Magaca alaabta
HWTS-CC019A-14 Noocyada Khatarta Sarreeysa ee Baabuloomavirus Aadanaha (16/18/52 Qorista) Qalabka Lagu Ogaado Asiidhka Nukliyeerka (Fluorescence PCR)
Epidemiology
Daraasaduhu waxay muujiyeen in caabuqyada HPV ee joogtada ah iyo caabuqyada badan ay yihiin mid ka mid ah sababaha ugu waaweyn ee kansarka ilmo-galeenka.Waqtigan xaadirka ah, daawaynta waxtarka leh ee la aqoonsan yahay ayaa weli ka maqan kansarka ilmo-galeenka ee uu keeno HPV, sidaas darteed hore u ogaanta iyo ka-hortagga caabuqa ilmo-galeenka ee uu keeno HPV waa furaha ka hortagga kansarka ilmo-galeenka.Aad bay muhiim u tahay in la sameeyo baaritaan fudud, gaar ah oo degdeg ah oo ogaanshaha etiology ee ogaanshaha kiliinikada iyo daaweynta kansarka ilmo-galeenka.
Kanaalka
Kanaalka | Nooca |
FAM | HPV 18 |
VIC/HEX | HPV 16 |
ROX | HPV 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 |
CY5 | HPV 52 |
Quasar 705/CY5.5 | Xakamaynta Gudaha |
Qiyaasaha Farsamada
Kaydinta | ≤-18℃ |
Nolosha shelf | 12 bilood |
Nooca Tuunada | Kaadi, suufka afka ilmo-galeenka, suufka siilka |
Ct | ≤28 |
LoD | 300 koobi/ml |
Gaar ahaan | Ma jiro falcelin falcelin ah oo leh shaybaarada kale ee neefsashada sida Hargabka A, Hargabka B, Legionella pneumophila, Rickettsia Q qandhada, Chlamydia pneumoniae, Adenovirus, Fayraska syncytial ee neefsiga, Parainfluenza 1, 2, 3, Coxsackie virus, Echo virus, Metapneu2 B1/B2, Virus syncytial Neefsashada A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Fayraska Boca 1/2/3/4, Chlamydia trachomatis, adenovirus, iwm iyo DNA genomic aadanaha. |
Qalabka lagu dabaqi karo | MA-6000-Waqtiga-dhabta ah ee Heerkulbeegga Heerkulbeegga ah (Suzhou Molarray Co., Ltd.) BioRad CFX96 Nidaamka PCR-waqtiga-dhabta ah iyo BioRad CFX Opus 96 Nidaamka PCR-waqtiga-dhabta ah |
Socodka Shaqada
1.Muunadda kaadida
J: Qaado1.4mL ee muunada kaadida si loo tijaabiyo oo centrifuge at 12000rpm 5 daqiiqo;Tuur xuubka sare (waxaa lagu talinayaa in laga ilaaliyo 10-20μL hoose ee tuubada centrifuge), ku dar 200μL oo muunad reagent ah, soo saarista ku xigta waa in loo fuliyaa si waafaqsan tilmaamaha isticmaalka Macro & Micro-Test Sample Siideynta Reagent (HWTS-3005-8).
B: Qaado1.4mL ee muunada kaadida si loo tijaabiyo oo centrifuge at 12,000rpm 5 daqiiqo;iska tuur dufanka sare (waxaa lagu talinayaa in laga ilaaliyo 10-20μL ee subagaynta hoose ee tuubada centrifuge), oo ku dar 200μL ee cusbada caadiga ah si dib loogu celiyo, sida muunada la tijaabinayo.Soo saarista ku xigta waxaa lagu samayn karaa Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaaso loo isticmaali karo Macro & Tijaabada Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. iyadoo la raacayo tilmaamahas loo isticmaalo.Mugga sare ee lagu taliyey waa 80μL.
C: Qaado1.4mL ee muunada kaadida si loo tijaabiyo oo centrifuge at 12,000rpm 5 daqiiqo;iska tuur dufanka sare (waxaa lagu talinayaa in laga ilaaliyo 10-20μL ee subagaynta hoose ee tuubada centrifuge), oo ku dar 200μL ee cusbada caadiga ah si dib loogu celiyo, sida muunada la tijaabinayo.Soo saarista ku xigta waxaa lagu samayn karaaQIAamp DNA Mini Kit (51304) ee QIAGEN ama Makro & Tijaabada Fayraska DNA/RNA Column (HWTS-3020-50).Soo saarista waa in loo habeeyaa si waafaqsan tilmaamaha isticmaalka.Mugga muunadda soo saarista waa 200μL, iyo mugga caddaynta lagu taliyey waa 80μL.
2. Muunada suufka afka ilmagaleenka/siilka muunada
J: Qaado 1ml ee muunada si loogu tijaabiyo 1.5mLof tuubada centrifuge,iyocentrifuge at 12000rpm 5 daqiiqo. Discard the supernatant (waxa lagu talinayaa in laga ilaaliyo 10-20μL ee subagaynta hoose ee tuubada centrifuge), ku dar 100μL ee muunada reagent sii daayo, ka dibna soo saar si waafaqsan tilmaamaha isticmaalka Macro & Micro-Test Muunad Release Reagent ( HWTS-3005-8).
B: Soo saarista waxaa lagu samayn karaa Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (kaaso loo isticmaali karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. iyadoo la raacayo tilmaamaha isticmaalka.Mugga muunadda la soo saaray waa 200μL, mugga sareynta lagu taliyeyna waa 80μL.
C: Soo saarista waxa lagu samayn karaa QIAamp DNA Mini Kit(51304) by QIAGEN ama Makro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Soo saarista waa in loo habeeyaa si waafaqsan tilmaamaha isticmaalka.Mugga muunadda soo saariddu waa 200 μL, mugga sare ee lagu taliyeyna waa80 μL
3. Xuubka afka ilmagaleenka/ Dhuunta siilka
Ka hor inta aanad muunada qaadin, isticmaal suufka si aad si tartiib ah uga tirtirto dheecaanka dheeraadka ah ee afka ilmo-galeenka, oo isticmaal suuf kale oo la dhex galiyay xalka ilaalinta unugga ama burushka muunada unugga ee afka ilmo-galeenka si aad ugu dhegto xuubka ilmo-galeenka oo u leexo saacadda 3-5 wareeg si aad u hesho unugyada afka ilmagaleenka exfoliated.Si tartiib ah u soo saar suufka suufka ah ama burushka,iyoku rid tuubo muunad leh 1ml oo cusbo ah oo nadiif ah. AKa dib markaad si buuxda u luqlushid, ku qalaji suufka ama burushka derbiga tuubada oo iska tuur, adkee furka tuubada, oo calaamadee magaca muunada (ama lambarka) oo ku qor tuubada muunada.